Более 1 000 000 datasheets например: LM317
Harris Corporation V36ZA80 - V36ZA80 (Harris Corporation) - Radial Lead Metal-Oxide Varistors
Наименование:
V36ZA80
Производитель:
Harris Corporation
Файл:
V36ZA80_Harris Corporation.pdf
Скачать datasheet:
Описание:
ZA Series
Data Sheet July 1999 File Number 2184.6
Radial Lead Metal-Oxide Varistors for Low to Medium Voltage Operation [ /Title The ZA Series of transient voltage surge suppressors are radial-lead varistors (MOVs) designed for use in the (ZA Series) protection of low and medium-voltage circuits and systems. Typical applications include motor control, telecom, /Subautomotive systems, solenoid, and power supply circuits to ject protect circuit board components and maintain data integrity. (Radial These devices are available in five model sizes: 5mm, 7mm, Lead 10mm, 14mm and 20mm, and feature a wide VDC voltage Metal- range of 5.5V to 615V. Oxide See ZA Series Device Ratings and Specifications table for Varispart number and brand information. tors for Low to Mediu m Voltage Operation) /Autho r () /Keywords (Littelfuse, Inc., Suppression Products, TVS, Transient Suppression, Protection, Automotive,
Features
• Recognized as “Protectors for Data Communications and Fire Alarm Circuits”, UL File #E135010 to Std. 497B • VDE Certified. License Number 116895E • Wide Operating Voltage Range VM(AC)RMS . . . . 4V to 460V • DC Voltage Ratings . . . . . . . . . . . . . . . . . . . 5.5V to 615V • No Derating Up to 85oC Ambient • 5 Model Sizes Available . . . . . . . . 5, 7, 10, 14, and 20mm • Radial-Lead Package for Hard-Wired or Printed Circuit Board Designs • Available in Tape and Reel or Bulk Pack • Standard Lead Form Options
Packaging
14MM, 20MM
5MM, 7MM, 10MM
4-34
1-800-999-9445 or 1-847-824-1188 | Copyright
В© Littelfuse, Inc. 1999
ZA Series
Absolute Maximum Ratings
For ratings of individual members of a series, see Device Ratings and Specifications chart. ZA SERIES Continuous: Steady State Applied Voltage: AC Voltage Range (VM(AC)RMS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Voltage Range (VM(DC)) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transient: Peak Pulse Current (ITM) For 8/20µs Current Wave (See Figure 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Pulse Energy Range (Note 1) For 10/1000µs Current Wave (WTM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Ambient Temperature Range (TA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Storage Temperature Range (TSTG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature Coefficient (αV) of Clamping Voltage (VC) at Specified Test Current . . . . . . . . . . . . . . . . . Hi-Pot Encapsulation (Isolation Voltage Capability) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301) . . . . Insulation Resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNITS
4 to 460 5.5 to 615
V V
50 to 6500 0.1 to 52 -55 to 85 -55 to 125